CytoLiner™ Fixed Cell Membrane Stains

Novel lipophilic fluorescent dyes for selective staining of the plasma membrane in formaldehyde-fixed cells. Available in 6 colors, from blue to near-IR.

Name SKU Size Availability Vendor Price Order

CytoLiner™ 680/710 Fixed Cell Membrane Stain, 250 labelings

30135-T 250 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 680/710 Fixed Cell Membrane Stain, 1000 labelings

30135 1000 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 650/675 Fixed Cell Membrane Stain, 250 labelings

30134-T 250 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 650/675 Fixed Cell Membrane Stain, 1000 labelings

30134 1000 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 570/590 Fixed Cell Membrane Stain, 250 labelings

30133-T 250 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 570/590 Fixed Cell Membrane Stain, 1000 labelings

30133 1000 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 495/510 Fixed Cell Membrane Stain, 250 labelings

30132-T 250 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 495/510 Fixed Cell Membrane Stain, 1000 labelings

30132 1000 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 410/450 Fixed Cell Membrane Stain, 250 labelings

30131-T 250 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ 410/450 Fixed Cell Membrane Stain, 1000 labelings

30131 1000 labelings Generally 1-2 weeks from receipt of order Biotium Log in for pricing

CytoLiner™ Fixed Cell Membrane Dyes are novel lipophilic fluorescent dyes developed specifically for selective plasma membrane staining in fixed cells for microscopy. The dyes are engineered for robust and consistent staining of formaldehyde-fixed cells, and are suitable for downstream immunofluorescence staining protocols.
 

Features Kit components
  • Robust and consistent staining of plasma membrane in formaldehyde-fixed cells
  • Suitable for antibody co-staining
  • Compatible with poly-L-lysine coated cultureware
  • Available in 6 colors from blue to near-IR
  • CytoLiner™ Fixed Cell Membrane Dye, 500X in DMSO
  • CytoLiner™ Fixed Cell Staining Buffer, 100X

Novel Membrane Dyes Designed for Fixed Cells
 
While classic lipophilic membrane dyes like DiI can be used to stain formaldehyde-fixed cells, staining can be highly variable due to the poor solubility of the dyes. CytoLiner™ Dyes are a new generation of membrane dyes uniquely engineered to permit selective staining of the plasma membrane in fixed and mildly permeabilized cells. CytoLiner™ staining is compatible with formaldehyde fixation and mild detergent permeabilization before staining. Staining can tolerate blocking agents used during immunofluorescence staining protocols, allowing subsequent staining with antibodies and other probes. The dyes also are compatible with poly-L-lysine coated cultureware and Transwell® permeable filter supports. CytoLiner™ Dyes are available in a selection of 6 colors from blue to near-IR.
 

Superior Staining Performance Over Classic Membrane Dyes
6/CytoLiner-vs-carbocyanine-dyes-composite-web
Comparison of fixed cell staining with CytoLiner™ Fixed Cell Membrane Stains versus classic lipophilic carbocyanine membrane dyes. In comparison to the traditional lipophilic carbocyanine dyes, CytoLiner™ dyes show more uniform and reliable staining of PFA-fixed, mildly-permeabilized cell membranes. PFA-fixed MCF7 cells were permeabilized for 10 minutes at RT with PBS/0.1% Triton® X-100, then rinsed with PBS and stained with carbocyanine dyes in PBS or CytoLiner™ Stains in 1X CytoLiner™ Buffer for 10 minutes at RT, then rinsed with PBS. Imaged by confocal microscopy; scale bar: 20 um.
Suitable for Co-Staining with Antibodies and Other Probes
CytoLiner-NucSpot-MCF7-composite-6-color
PFA-fixed MCF-7 cells were permeabilized with PBS/0.1% Triton® X-100 for 10 minutes at room temperature, then stained with 1X CytoLiner™ Fixed Cell Membrane Dyes and NucSpot® Nuclear Stains. 


Find the Right Stain for Your Application
 
CytoLiner™ Dyes are part of Biotium’s family of unique and innovative cell membrane stains designed for specific applications. For workflows requiring staining live cells before fixation, we recommend our CellBrite® Fix Membrane Stains or MemBrite® Fix Cell Surface Staining Kits. Biotium also offers CF® Dye conjugated lectins, including Concanavalin A (Con A) and Wheat Germ Agglutinin (WGA), for visualizing cell surfaces in live or fixed cells. For longer term monitoring of cell surfaces in live cells, we recommend CellBrite® Steady Dyes. To find the right stain for your application, see our Membrane & Cell Surface Stains Comparison, or download our Membrane & Surface Stains Brochure.

Watch our video where Technical Applications Scientist II, Jacqueline Steenhuis PhD answers your top questions about Biotium’s various membrane stains for fluorescence microscopy.

MemBrite® Fix Cell Surface Staining Kits – Biotium

 
For additional support or product recommendations, contact us at info@genetargetsolutions.com.
 

CytoLinerStains
wp_reset_postdata();